6 4 A c c e s s t o w e r i n P a n a t r a p Start section on the ground (m) according to la standard NF E 85-016 on safety ladders. • 0 < H ≤ 0.50 = Panacier without ladder (see image 1). • 0.50 < H ≤ 1.00 = single 3.12 m ladder on the ground as in image 2 ( buckling length 2.50 m). • 1.00 < H ≤ 1.80 = outer ladder with guardrail at 3.00 m as in image 3. • 1.80 < H ≤ 2.00 = Panatrap ladder on the ground (see image 1 without Panacier). 2.00 m standard Anchor MDS guardrail Panatrap Ledger Panacier Toeboard 3.00 m standard Diagonal brace Basic standard Adjustable baseplate 0.70 m or 1.00 m 2.00 m to 3.00 m Compliant with standard NF P 12811-1 NF EN 12811-1 Access tower Overhead clearance ≥ 1.90 m 1.93 m Working load 1 kN/m 2 4.50 kN/m 2 Distance between the main rail and the deck > 950 mm 993 mm Maximum gap between guard rails < 470 mm 452 mm Landing toeboard ≥ 150 mm 150 mm Access openings min. 0.45 m x 0.60 m 0.53 m x 0.75 m 1 2 3 H 2.00 H H 01.11.17 T e c h n i c a l i n f o r m a t i o n