Technical information Crab range

Use of brackets causes horizontal stress that limits the bearing capacity of the standards. B r a c k e t s 2 6 Brackets With them you can widen the access or working area to the desired level, or bring it closer to the façade to get round a protrusion, offset the scaffolding or fill in a gap. They have a clamp with a wedge key at one end to fit into the stirrups on the standards. Part number Length in m Weight (kg) Load capacity (kN) Uniformly distributed concentrated 250703-6 0.30 1.62 3 1.5 321703-1 0.35 with sliding foot 3.60 3 1.5 250705-1 0.50 3.64 5.7 3.3 250707-7 0.70 4.50 5 3.3 251707-6 0.70 with sliding foot 7.39 5 3.3 250710-1 1.00 8.06 5 3.3 * A guardrail can be placed at the end of the 0.50, 0.70 and 1.00 m brackets using a sliding foot on ledger or a 1.00 m post with wedge coupler. 0.30 m 0.50 m * 0.50 m 0.70 m 0.50 m 0.25 m 0.27 m 0.35 m 0.27 m 0.50 m 0.70 m * 1.00 m 1.00 m * Sliding foot on ledger Allows placement of new standards that are not resting on the ground. Part number Description Weight (kg) 250000-7 Sliding foot on ledger 2.25 1.00 m post with wegge coupler Equipped with a wedge coupling, it is fitted to the end of bracket or on ledgers as guardrail standard. Part number Description Weight (kg) 250111-2 1.00 m post with wedge coupler 5.51 0.50 m 0.50 m 0.50 m 0.25 m 01.11.17 T e c h n i c a l i n f o r m a t i o n