Technical information Crab range
Assembling and dismantling with temporary erecting guardrail 2 0 • From the lower level, fit temporary erecting guardrails. • Fit the final return safety guardrails. • Fit the “No entry” sign. • From the lower level, lay the deck in all the grid sections of the first floor. • Fit ledgers at 0.50 m and 1.00 m to assemble the first floor guardrail. • Place and lay the adjustable baseplate on the spacing shims. • Interlock the basic standards. • Fit the ledgers. • Level up. • Instal the firts platform to facilitate erection. • Complete the platform inside the grid. • Fit the 3.00 m standards. • Place ledgers at 2.00 m and temporarily at 1.00 m. • Fit the 2.00 m standards. • Fit the ledgers on the upper deck and the third ledger in the access grid section. • Move the temporary erecting guardrails to the upper floor. • Secure the structure with ties as erection progresses. 1 2 3 4 5 6 7 8 9 When due to certain circumstances the safety guardrail or MDS guardrail cannot be fully or partially fitted, the temporary erecting guardrail is an alternative solution for collective protection. It is fitted from the lower level to ensure safety on the upper level. 01.11.17 T e c h n i c a l i n f o r m a t i o n