Technical information Crab range

Sens de portée C a p a c i t y o f t h e d e c k s Sens de portée L Bracket I L L Bracket I Capacity of the decking Continuous deck arrangement The capacities of the decking in the tables opposite (in kN/m 2 ) are limited by the capacities of the: - Panacier under evenly distributed load, - load-bearing ledgers bending with sag limited to 1/200°. NB: Check the overall stability of the load- bearing structure under the combined vertical and horizontal loads. Capacity of the prefabricated brackets The capacities of prefabricated brackets in the tables opposite (in kN/m 2 ) are limited by the capacities of the: - Entrepose Panacier under evenly distributed loads, - load-bearing brackets bending with sag limited to 1/200°. NB: note the additional loads exerted on the structure by the diagonals. Check the overall stability of the load- bearing structure under the combined vertical and horizontal loads. Ledger Deck length 70 100 150 200 250 300 35 6.00 6.00 6.00 6.00 6.00 4.50 50 6.00 6.00 6.00 6.00 6.00 4.50 70 6.00 6.00 6.00 6.00 6.00 4.50 100 6.00 6.00 6.00 5.78 4.58 3.78 150 6.00 5.18 3.38 2.48 1.94 1.58 180 4.70 3.22 2.07 1.50 1.15 0.92 200 3.35 2.28 1.44 1.03 0.78 250 1.69 1.12 300 0.99 Ledger Deck length reinforced 70 100 150 200 250 300 100 6.00 6.00 6.00 6.00 6.00 4.50 150 6.00 6.00 6.00 6.00 6.00 4.50 200 6.00 6.00 6.00 4.61 3.64 3.00 250 6.00 6.00 4.00 2.94 2.31 1.89 300 4.16 2.84 1.82 1.31 1.00 0.80 Ledger Deck length 70 100 150 200 250 300 35 6.00 6.00 6.00 6.00 6.00 4.50 50 6.00 6.00 6.00 6.00 6.00 4.50 70 6.00 6.00 6.00 6.00 6.00 4.50 100 6.00 6.00 6.00 6.00 6.00 4.50 150 6.00 6.00 6.00 5.18 4.10 3.38 180 6.00 6.00 4.37 3.22 2.53 2.07 200 6.00 4.78 3.11 2.28 1.78 1.44 250 3.60 2.46 1.56 1.12 0.85 300 2.20 1.48 0.91 Ledger Deck length reinforced 70 100 150 200 250 300 100 6.00 6.00 6.00 6.00 6.00 4.50 150 6.00 6.00 6.00 6.00 6.00 4.50 200 6.00 6.00 6.00 6.00 6.00 4.50 250 6.00 6.00 6.00 6.00 4.84 4.00 300 6.00 5.91 3.86 2.84 2.23 1.82 Capacity of the decking check pattern deck arrangement The capacities of the decking in the tables opposite (in kN/m 2 ) are limited by the capacities of the: - Panaciers under evenly distributed load, - load-bearing ledgers bending with sag limited to 1/200°. NB: Check the overall stability of the load- bearing structure under the combined vertical and horizontal loads. Bracket Deck length 70 100 150 200 250 300 30 6.00 6.00 6.00 6.00 6.00 4.50 50 6.00 6.00 6.00 6.00 6.00 4.50 70 6.00 6.00 6.00 6.00 5.49 4.50 100 6.00 6.00 6.00 4.78 3.78 3.11 continuous section Bracket Deck length 70 100 150 200 250 300 30 6.00 6.00 6.00 4.78 3.78 3.11 50 6.00 6.00 6.00 5.48 4.34 3.58 70 6.00 6.00 4.54 3.35 2.63 2.16 100 6.00 4.78 3.11 2.28 1.78 1.44 isolated section 6 Classes of scaffolding 5 4 3 2 155 Span direction pan direction 01.11.17 T e c h n i c a l i n f o r m a t i o n

RkJQdWJsaXNoZXIy OTQ2MzM=