Technical information Crab range

Admissible loads of the standards Compressive (kN) For façade scaffolding anchored in a zigzag pattern with one side section out of two, in accordance with standards NF EN 12810 and NF EN 12811: • every 8.00 m Q = 18.69 kN in Multicrab Q = 30.50 kN in Crabétai • every 4.00 m Q = 24.44 kN in Multicrab Q = 39.21 kN in Crabétai For other types of scaffolding, the loads depend on the ledger height in correlation with the triangulation: Upright Buckling length of 2.00 m Multicrab 24.44 Crabétai 39.21 For other configurations, calculations carried out by a competent design and engineering firm are required on a case-by-case basis. Tensioning (kN) Type of connection Pin HM10 Bolt HM12 Bolt HM10 Bolt HM12 Bolt Upright quality 6-8 quality 6-8 quality 8-8 quality 8-8 Multicrab 10.22 20.59 29.93 27.62 40.14 Crabétai 15.97 20.59 29.93 27.62 40.14 For the old models of Multicrab standard equipped with crimped bolted spigot, tensile strength is limited to 2000 kN. Bending with load concentrated in the middle of the span (kN) Section 0.35 0.50 0.70 1 .00 1.50 1.80 2.00 2.50 3. 00 MN 12.30 9.10 6.80 5.10 3.65 3.10 2.80 1.90 1.40 MR 11.87 13.33 7.47 4.13 2.60 MP 10.33 6.87 4.33 6.00 5.43 4.33 3.60 Admissible loads of the ledgers Compressive Section 0.35 0.50 0.70 1 .00 1.50 1.80 2.00 2.50 3. 00 MN 19.50 19.50 19.50 19.50 19.50 19.50 19.50 17.93 12.49 MR 19.50 19.50 19.50 19.50 19.50 MP 19.50 19.50 19.50 19.50 19.50 19.50 19.50 MN: normal ledger - MR: reinforced ledger - MP: deck ledger Tensioning: 20.40 kN Bending with evenly distributed load (kN) Section 0.35 0.50 0.70 1 .00 1.50 1.80 2.00 2.50 3. 00 MN 22.70 21.33 16 .00 12.00 8.10 6.20 5.00 3.35 2.55 MR 24.33 23.33 19.33 15.83 9.20 MP 16.33 11.67 8.80 10.47 9.20 7.10 5.73 Admissible loads of the intermediate cross beams Length in m Load capacity (kN) Uniformly distributed concentrated 0.70 10.19 5.09 1.00 7.13 3.57 1.50 3.62 2.26 2.00 2.03 1.27 2.50 1.30 0.81 3.00 0.90 0.56 Admissible loads of the beams Length in m Load capacity (kN) Uniformly distributed concentrated 4.00 28.00 22.00 5.00 24.00 22.00 6.00 21.60 18.93 Admissible loads of the diagonal braces Tensioning: 12.00 kN Compressive (kN) Grid size Theoretical length Load theoretical height x length (m) (m) 1.00 x 0.70 1.17 12.00 1.00 1.35 12.00 1.50 1.72 12.00 2.00 2.15 10.31 2.50 2.60 7.15 1.50 x 0.70 1.62 12.00 1.00 1.75 12.00 1.50 2.06 11.18 2.00 2.42 8.22 2.50 2.84 6.03 2.00 x 0.70 2.09 10.88 1.00 2.19 9.95 1.50 2.45 8.03 1.80 2.63 6.99 2.00 2.76 6.37 2.50 3.13 4.98 3.00 3.53 3.93 Admissible loads of the brackets Length in m Load capacity (kN) Uniformly distributed concentrated 0.30 3.00 1.50 0.50 5.70 3.30 0.70/0.70 angled / 1.00 5.00 3.30 C o m p o n e n t r e s i s t a n c e 154 . 01.11.17 T e c h n i c a l i n f o r m a t i o n

RkJQdWJsaXNoZXIy OTQ2MzM=