Technical information Crab range
Crabtour : Assemb l i ng and d i smant l i ng a 6 standards tower • Fit and adjust the telescopic standards, the adjustable heads and the fork heads. • Fit the adjustable ledgers and diagonal braces on the adjustable heads of the first section. 10 11 • Move the 4 x 0.30 m Panacier while moving backwards inside the tower. • Mandatory wind bracing of the central side section with one ledger and one diagonal. • Move the Panatrap. • From the lower level, move the 2 remaining Panacier and fix the access ladder under the Panatrap. • Refit the upper level and continue assembling repeating steps 3 to 9 as many times as necessary. 8 9 The central side section must be wind-braced with diagonals and ledgers on all levels. Dismantling: dismantle the tower in the reverse order of assembly. 133 • Mandatory wind bracing of the central side section with one ledger and one diagonal. • Finish the terminations and adjust the last 2 bases of the forks. • Dismantle the 2 temporary Panacier. • Inspect the tower and draft the acceptance report. Allow 2 1.50 m x 0.30 m Panacier for erecting and dismantling. 01.11.17 T e c h n i c a l i n f o r m a t i o n