Technical information Crab range
To u r é c h a f : s p e c i a l a s s e m b l i e s 117 or a corner bracket Corner bracket Brackets with base The base can be used to create a bracket. The admissible load at the end of the bracket is limited to 5 kN. For heavier loads, a case study is needed. The load on the bracket is taken by the load-bearing standard. The tower must be stabilized using an anchorage system or correctly proportioned wind bracing. Anchor tie Stop 0.70 m Wind bracing Assembling the bracket and the top level of the tower from the lower level (frame + standard) Adding a bracket from the top level of a tower that has already been erected (2 standards + ledgers + diagonals) Using standards to accommodate different heights The Touréchaf is used to create top or bottom shoring structures with single standards wind-braced by diagonals. Difference in height between 2 towers Different heights at top Different heights at bottom 0.5 m or 1.0 m standard 0.5 m or 1.0 m standard Diagonal Diagonal Anchor tie 0.50 m upright + 1 m 1.12 m diagonal 1.00 0.70 Formwork with cap Work platforms around rim formwork are made with overhanging Multicrabs. 01.11.17 T e c h n i c a l i n f o r m a t i o n