Technical information Crab range

109 MULTICRAB - TECHNICAL INFORMATION - 2023 MULTICRAB ASSEMBLY •When moving, attach the free tether before detaching the other one. •When the level is totally secure, assemble the next level repeating steps 3 and 4 (the 3.00 m uprights are now replaced with 2.00 m ones). 7 •Fit stops or anchors at 4.00 m. •Continue assembly repeating steps 5 and 6. 8 9 •For an upper service area with 3 levels, continue assembling following steps 7 and 8. •Fit stops or anchors as assembly progresses every 2 levels (4.00 m). •Inspect the scaffold and put the inspection report in the pocket on the "No entry" sign. Dismantling is to be done in the reverse order of assembly. INFO Class 5 (450 daN/m²) VARIOPAN Standard grid section 1.50 m Outer lateral protection with standard MULTICRAB ledgers. INFO

RkJQdWJsaXNoZXIy OTQ2MzM=